CLEANROOM PACKAGE SOLUTIONS

2014年6月12日星期四

Foreign trade Sales Clerk Exams-Air Filters

Foreign trade Sales Clerk Exams-Air Filters
Name:                           Points:
B. Air filter products fill in the blank in English, 2 points each space.
1) Air Filters overall divided into: (          ) (          ) (          ) (          )
2) Please list efficiency of below air filter:
Primary Air Filter
Secondary Air filter
HEPA air filter
ULPA air filter
3) Cited three different styles of HEPA filter           ) (          ) (          )
4) Cited three kinds frame material of Mini-pleated HEPA filter (       ) (       ) (       )
5) There separator materials of HEPA filter with Clapboard: ( ) ( )
6) Efficiency bag filter another English Name:





2014年6月11日星期三

Foreign trade Sales Clerk Exams(1)---Cleanroom Equipment

Foreign trade Sales Clerk Exams(Cleanroom Equipment)
Name:                           Points:
A. Equipment products fill in the blank in English, 2 points each space.
1) We cited three standard models Air shower (                     ) (                   ) (                      )
2) Cited three Air shower cabinet material (                    ) (                         ) (                        )
3) write all materials of Air shower door in quote sheet: (                  ) (                 ) (               )
4) Write the three material used for our FFUs (                    ) (                     ) (                       )
5) Write 3m deep Air shower price calculating format (available with Chinese):
6) Our laminar flow clean bench what are the two types? (                           ) (                        )
7) Two types material for clean bench: (                                  ) (                                   )
8) Write clean workbench price calculate format (available with Chinese):
9) HEPA filter Box Chinese name is:
10) Our pass box overall which is divided into three types: (               ) (               ) (              )
11) Transfer window interlock device two types are: (                        ) (                           )
12) FFU which mainly consists of two parts: (                              )(                                )
13) Standard pass box with air shower’s nozzle is what kind material?
14) Purification level of modular cleanroom give three: (                ) (                  ) (                 )
15) Cited two frame material of clean booth: (                            ) (                         )
16) What’s the clean bench clean class level?(                                )

17) FFU wind speed range: (                                )


Invigilator: Vanessa Wang
Job title: International Dept. Manager
Company webisite: www.anlaitech.com
      or          www.cleanroomffu.com

How many points you can get?:-)

2014年6月9日星期一

What is the FFU (laminar flow hood)?

What is the FFU (laminar flow hood)?
FFU (Fan Filter Unit) is a combination of fan and filter can also be called “Motorized HEPA filtration equipment”. FFU are usually installed in the supply end of the clean room, usually placed on the T-grid with gasket sealed.
FFU upper part is the fan module, the lower part is the filter. Accordance with the requirements of cleanliness filters for different levels of efficiency (HEPA) or ultra-efficient (ULPA) filters provide clean air for the clean room. Fan modules overcome the resistance of the HEPA filter, but also to overcome the resistance of the whole cycle all channels of wind components in order to maintain the set running speed. Design and construction of FFU system with simple characteristics, flexible air flow adjustment, easy to change in the clean area, so the system has become one of the popular forms of industrial clean room.


FFU (laminar flow hood) Features:
1: Flexibility. Because limiting FFU self-powered, it is not limited by region. In a huge clean room can divided into zoning control according to need. Moreover, with the change in the semiconductor manufacturing process, plant layout is bound to be adjusted accordingly, flexibility FFU makes this adjustment easier, and will not bring secondary investments.
2: Reusability. If the FFU no need use at moment can be removed, sealed, safekeeping for next using.
3: Negative pressure ventilation. This is the unique characteristics of FFU, because of its own to provide anti-static, making relative to the clean air plenum plant negative, thus, the particles inside static pressure under pressure will not leak to clean area, make sealant becomes very simple and safe.
4: Shorten the construction period. Eliminating the need for the use of FFU duct fabrication and installation because the air duct in a clean project, takes up a lot of the construction period , any investor wants to invest as soon as possible to bring income , the choice of FFU become a possibility .
5: To reduce operating costs. Although the selection of FFU, the initial investment than with high ventilation duct, but during running, the outstanding performance of energy-saving, maintenance-free characteristics, with a 40% reduction in cycle operating costs.

FFU (laminar flow hood) external residual pressure (ESP): In a set speed, the total static pressure FFU (TSP), net of HEPA / ULPA filter resistance, that is external residual pressure (ESP), the unit is Pa. ESP is the FFU ability to overcome resistance in the clean room air circulation, either dimension the overall static TSP FFU and pressure or fan outside the machine module are required supply airflow volume, or no meaning.
Input energy (input power consumption): normal operation of FFU input voltage and input current the unit is W. Obviously, FFU that run at different condition of airflow volume and total static pressure, enter a different energy. Therefore, if you do not specify the operating point, the value of the input energy does not make sense.
Unit noise (noise level): according to the standard IES-RP-CC002, the normal operation of the FFU from the surface of the wind noise level at the center is 1.2mm below the unit is dB (A). FFU run at different conditions of airflow volume and total static pressure, different noise. Therefore, if you do not specify the operating point, the noise level does not make sense.
FFU (laminar flow hood) fretting (micro vibration): According to the standard IES-RP-CC002, FFU vibration amplitude and vibration rate at the maximum operating conditions point unit are mm and mm / s.
Uniformity air velocity (air uniformity): according to the standard IES-RP-CC002, the normal operation of FFU, the distance by measuring the surface side of the wind 150mm (6 ") of the horizontal surface wind speed, the average value of the obtained average wind speed. minimum and maximum wind speed and air deviation than is uniformity in units of + / - % standard IES-RP-CC002 FFU required air velocity at any point of its average wind speed deviation should be within + / - 20% or less .
Air Filter efficiency (filter grade): according to the European standard EN1822, HEPA Filter class from H10-H14, U15-U17. Or according to the American standard MIL-282 (HEPA), for 0.3um efficiency values ​​; according to the American standard IES-RP-CC007.1, for 0.12um efficiency values.

Factory Mini-Pleated HEPA filter Test Report


Mini-pleat HEPA filter test report

Product Name
Mini-pleat HEPA filter
Test Temperature
23.24
Product Size
457*457*78mm
Test Humidity
58.6%RH
Efficiency
99.99%@0.3μm
Filter resistance
152Pa
Air velocity
0.9m/s
Rating air flow
650m3/h
Test Criterion
EN1822——45

Particleμm
UpstreamPCS
 Downstream(PCS)
Efficiency (%)
0.1 ~0.2
2158515
1027
99.952421
0.2 ~0.3
1206475
79
99.993452
0.3 ~0.5
795906
14
99.998241
0.5 ~0.7
221238
1
99.999548
0.7 ~1.0
12464
0
100
1.0
3245
0
100






Result
Pass
Date

Tested by

Auditing

Approval

Package No.
H13-1/75
Remark


Anlai Mini-pleated HEPA filter:




Factory Checking: www.cleanroomffu.com

HEPA filter Management Tel:+86-20-26231609

Quality Service Skype: wangvanlu








2014年6月5日星期四

What clean class level of Clean Booth required by Touch Screen Industry?

What clean class level of Clean Booth required by Touch Screen Industry?

1, Emphasis: touch screen laminating process, generally do 100clean class level, is designed to produce the most qualified products, reduce losses and increase revenue, on time delivery.

2, Rest of the program: generally do 1000 and 10000class.
Clean shed, shed purification, modular cleanroom  (laminar flow clean shed, purification shed, clean studio clean operation Pavilion, CLEANBOOTH): is an industrial aluminum ( or stainless steel square tube, square tube iron spray ) as a scaffold , using centrifugal fan filter machine air, surrounded by anti- static power grid curtain ( or glass ) , internal purification level of up to 100;
Especially for partial purification workshop area of ​​high -level requirements, such as assembly line work area. Clean shed provided by Anlai purification technology, top quality, good looks, and affordable. "AL" brand of Dust sefl clean shed provide by Anlai Technology production. Anlai Technologies is a professional air purification equipment manufacturer; the company has serviced for tens of thousands of well-known customers!

3. Clean Booth features:
1, the assembly structure design, easy installation, greatly shortens the delivery cycle;
2, easy to move (can be mounted caster);
3, modular structure, easy to raise the level of purification, scalability, and reuse of high value;
4, relatively clean benches, large interior space available and effective; relatively traditional clean room, low cost, fast construction, and low height of the floor.

4. Reliable material
1, Stand: 50 * 50 industry-specific stainless steel 304 solid, beautiful, no rust, no dust production
2, anti-static curtain: 0.3mm thick mesh (imported from Korea) anti-static effect, transparency, mesh clear, flexibility is good, no deformation, not aging.

3, the core part of the clean studio with a warranty period of one year FFU laminar flow hood , low noise , safe to use .

Epoxy powder coated steel framewrok:


Control box:

Epoxy powder coated steel with anti-stiac air curtain


Stainless steel with plexiglass

Source from: www.cleanroomffu.com
Prepared by Vanessa, Engineer at Anlia Cleantech Co.,Ltd
Skype: wangvanlu

2014年6月3日星期二

GMP Cleanroom Required-drug Transfer Vehicle

GMP Cleanroom Required-drug Transfer Vehicle

1 Introduction
Mobile car clean (clean transport vehicles ) is a portable built-in DC power supply can be electric lift , providing partial class A -class environment , removable purification equipment ; It is widely used in the pharmaceutical industry, pharmaceutical exports from filling to Drug transporters lyophilize between transport medicine boxes and industrial equipment brought into the filling line inside ; can quickly and seamlessly effectively filling isolator (RABS) docking and docking with the lyophilize dust protection to ensure drug transport and docking in class A level area.

2 Structure Description
Mobile car clean (clean transport vehicles ) from the chassis, high efficiency filter, variable air volume air handling units , several major components of rechargeable power pack , electric lifting mechanism and other components. No fingerprint stainless steel cabinet with mirror SUS304 production, sheet metal bending one made
​​of beautiful clean , easy to clean and disinfect .
Mobile car clean (clean transport vehicles ) with a variable air volume fan system , by adjusting the working conditions the fan , make a clean workspace average wind speed remains within the rated range (0.45m / s), keeping the work area cleanliness and under positive pressure , effectively extending the moving vehicle main components HEPA filter life.

3 The main components HEPA filter life.
Mobile car clean (clean transport vehicles) flow manifold for the vertical flow. Air from top to bottom , flows through the lift platform protection drugs and around the lifting platform between the PC board and the formation of air protection retaining walls , internal and external form positive pressure when moving car clean (clean transport vehicles ) moving process to ensure the cleanliness of the work area for the class A grade .
Mobile car clean (clean transport vehicles) with electric lifting mechanism driven mobile platform. May be stopped at any vertical position. Upper and lower limit switches to ensure that the platform activities between highest and lowest position.
Mobile car clean (clean transfer vehicle) three-sided PC board envelope, moving up and down the side of the door, to ensure that when moving vehicle docking sealed envelope with the isolation and positioning.

4 the technical parameters
Clean class level
Class A
Air velocity
  0.360.54m/s
Air flow type
Vertical air flow
Noise
56dB(A)
Lifting mechanism

Electric up and down movements ,
Power supply : 24V
Stroke : 500mm
Load : 200kg
Lift Control
Up, down button switch,
Can be stopped at any position
HEPA filter
DOP,HEPA efficieny99.997%,
Inside and outside Different Pressure
10Pa
Charging power and time
AC220V/50HZ/1A/8h
Fully charged battery life
   5H
Working area
W930*D450*H700
External Size
W1050*D560*H1800


2014年6月2日星期一

GMP Clean room renovation equipment and instruments -100L dust particle counter

GMP Clean room renovation equipment and instruments -100L dust particle counter

1. The main feature:
● sample volume 100L / min of
● Built-in flow sensor
● Touch screen control operation
 ● M3/100L unit selection
 ● Count report meets GMP/ISO14644/209E, ISO21501-4


2. Specification
Dimensions
280 x 380 x 340mm3(宽××高)
Display
800,480 16.7M resolution color touch screen touch / display
Weight
6kg
Maximum power consumption
80W
Power supply
AC220V 50Hz
Size channels
0.51351025μm
Test mode
Single , repeated continuously calculates , GBMODEL (UCL)
Sampling flow
Imported sampling pump 100L/min
Sampling time
Optionally between 1 second and 99 minutes 59 seconds
Sampling frequency
1-99 times or continuous testing
Self-Purification time
≤10min
Printer
Built-in thermal printer
Counting alarm
Any value set for each channel
Maximum allowable concentration sampling
35000 / L
Extended working hours
8Hourse
Light and life
Semiconductor lasers ( life of more than 30,000 hours )
Data Storage
2000 group
Environmental Conditions
Temperature10-35
Humidity20%-75%
Optional