What is the difference between clean booth
and modular clean room?
1. Clean booth
Clean booth, also known as clean shed / softwall clean room / ISO5 laminar flow clean booth /1000class ISO6 clean booth/ 10,000 modular clean room, transparent plastic sheeting to prevent static electricity in the chaotic stream of clean room space surrounded by a small space, using HEPA or ULPA and independence of air conditioning units and become a more senior of the clean room, the level of 100 to 10,000 , the interior space of about 2.0 meters in height, covering an area of about 50m2 or less, four pillars can be installed wheels, for flexibility in the use, supporting Air shower use.
1. Clean booth
Clean booth, also known as clean shed / softwall clean room / ISO5 laminar flow clean booth /1000class ISO6 clean booth/ 10,000 modular clean room, transparent plastic sheeting to prevent static electricity in the chaotic stream of clean room space surrounded by a small space, using HEPA or ULPA and independence of air conditioning units and become a more senior of the clean room, the level of 100 to 10,000 , the interior space of about 2.0 meters in height, covering an area of about 50m2 or less, four pillars can be installed wheels, for flexibility in the use, supporting Air shower use.
2. Clean booth material :
Framework clean booth generally three types: stainless steel square pass, iron square pass, aluminum.
Clean the top shelf material generally three types: stainless steel, cold rolled steel spray , anti -static power grid around the curtain , (anti-static ) acrylic sheet .
Clean air section , the general choice FFU laminar flow hood (FFU laminar flow air supply unit )
Clean booth envelope materials generally include : anti-static curtain around , (anti-static ) acrylic sheet.
Framework clean booth generally three types: stainless steel square pass, iron square pass, aluminum.
Clean the top shelf material generally three types: stainless steel, cold rolled steel spray , anti -static power grid around the curtain , (anti-static ) acrylic sheet .
Clean air section , the general choice FFU laminar flow hood (FFU laminar flow air supply unit )
Clean booth envelope materials generally include : anti-static curtain around , (anti-static ) acrylic sheet.
3. clean booth purification level
selection:
More customers will choose one thousand clean booth , or ten thousand clean booth , a small number of customers will choose one hundred or ten thousand . In short, clean booth -level choices that customers need cleanliness may be, but relatively clean booth closed , such as when selecting clean booth level is relatively low , they tend to bring some side effects : insufficient cooling capacity , will shed staff in a clean I feel more hot, so the actual and the customer communication process , you need to pay attention to this point.
More customers will choose one thousand clean booth , or ten thousand clean booth , a small number of customers will choose one hundred or ten thousand . In short, clean booth -level choices that customers need cleanliness may be, but relatively clean booth closed , such as when selecting clean booth level is relatively low , they tend to bring some side effects : insufficient cooling capacity , will shed staff in a clean I feel more hot, so the actual and the customer communication process , you need to pay attention to this point.
4. The cost of the clean and dust-free
workshop shed comparison:
Generally speaking , most customers will clean booth built in the clean room , but some customers do not want to build a separate clean room, clean booth in the air conditioning system and does not consider air shower , pass the case of window cleaning equipment , etc. cost clean booth is about 40% to 60% clean room cost , depending on the customer 's choice of clean booth material , as well as the size of the clean booth . The greater the need to clean the area , the cost of clean and dust-free workshop shed will be smaller compared to the difference.
Generally speaking , most customers will clean booth built in the clean room , but some customers do not want to build a separate clean room, clean booth in the air conditioning system and does not consider air shower , pass the case of window cleaning equipment , etc. cost clean booth is about 40% to 60% clean room cost , depending on the customer 's choice of clean booth material , as well as the size of the clean booth . The greater the need to clean the area , the cost of clean and dust-free workshop shed will be smaller compared to the difference.
5. clean booth advantages:
A. Construction of fast, easy installation
B. low cost , easy maintenance
C. easy to control , FFU each comes with fan;
A. Construction of fast, easy installation
B. low cost , easy maintenance
C. easy to control , FFU each comes with fan;
6. clean booth drawbacks:
A. because of the extensive use of FFU fan filter unit , so clean booth noise may be relatively large ;
B. FFU comes with fan , fan and more, to maintain high frequencies ;
C. due to reasons of space air , clean shed will often feel hot ;