Cleanroom Industry Standards
Cleanrooms are essential to any manufacturing process where particulate contamination can affect the quality of goods produced. Cleanrooms provide secure environments with controlled air filtration, lowering the possibility of product contamination or large particulate interference with critical process manufacturing. Cleanrooms are used in industries such as medical device manufacturing, food processing, computer manufacturing and server holding, military and aerospace research and life sciences as well as thousands of other potential applications.
Cleanrooms are essential to any manufacturing process where particulate contamination can affect the quality of goods produced. Cleanrooms provide secure environments with controlled air filtration, lowering the possibility of product contamination or large particulate interference with critical process manufacturing. Cleanrooms are used in industries such as medical device manufacturing, food processing, computer manufacturing and server holding, military and aerospace research and life sciences as well as thousands of other potential applications.
Cleanroom Industry Requirements & Classifications
Cleanroom standards are classified according to the number and size of particles permitted per volume of air in a specific amount of time. Clean Air Products engineers can provide guidelines for the class of cleanroom required. Typically, businesses and organizations are aware of their cleanroom performance requirements because of customer, industry or government specification. For example, government regulation USP 797 outlines specific requirements for pharmaceutical product manufacturing.
Clean room industry requirements are classified according to ISO 14644-5:2004 which specifies basic requirements for cleanroom operations. Federal Standard 209E is still also used (see Table 1).
ISO cleanroom classifications are rated according to how much particulate of specific sizes exist per cubic meter (see second chart). The "cleanest" cleanroom is a class 1 and the "dirtiest" a class 9. Each clean room is rated by ISO class. This cleanroom standard rating system provides the necessary information to make an informed decision based on your product needs. Most clean rooms fall into the class 6,7, or 8 categories.
Clean room industry requirements are classified according to ISO 14644-5:2004 which specifies basic requirements for cleanroom operations. Federal Standard 209E is still also used (see Table 1).
ISO cleanroom classifications are rated according to how much particulate of specific sizes exist per cubic meter (see second chart). The "cleanest" cleanroom is a class 1 and the "dirtiest" a class 9. Each clean room is rated by ISO class. This cleanroom standard rating system provides the necessary information to make an informed decision based on your product needs. Most clean rooms fall into the class 6,7, or 8 categories.
Configuration:
Parameter
|
Softwall Clean Booth
|
Hardwall Clean Booth
| |
Cleanliness
|
From Class 100 to Class 10,000
| ||
External Dimension
|
As per requirement
| ||
FFU
|
Dimension
|
2'X4'
| |
Cabinet Material
|
Stainless Steel
| ||
Power source
|
110V/60hz/av/dc, 220V/60HZ/AV/DC
| ||
HEPA Filter
|
H14 Hepa filter
| ||
Frame Material
|
Stainless Steel
| ||
Wall Material
|
Anti-static soft PVC wall 106~109Ω
|
Anti-static acrylic 106~109Ω
| |
Lighting
|
Lamps
|
Available in LED and T5
| |
Air condition
|
As per requirement
|
Available in constant temperature air conditioner/constant temperature and humidity conditioner
|
Besides above configuration, we can customized as required.
Technical Paremeters:
Class Level
|
Model
|
Inner dimension
|
Number of
|
Air volume(m3/h)
|
W * D * H (mm)
|
FFU
| |||
Class100
(ISO5)
|
ALCS6 * 8
|
2000 * 3000 * 2400
|
6
|
6600
|
ALCS 8 * 12
|
2440 * 3660 * 2400
|
12
|
13200
| |
ALCS 8 * 16
|
2450 * 4880 * 2400
|
16
|
17600
| |
ALCS 8 * 20
|
2440 * 6100 * 2400
|
20
|
22000
| |
Class 1000
(ISO6)
|
ALCS6 * 8
|
2000 * 3000 * 2400
|
2
|
2200
|
ALCS 8 * 16
|
2440 * 4880 * 2400
|
4
|
4400
| |
ALCS 12 * 16
|
3660 * 4880 * 2400
|
6
|
6600
| |
ALCS 20 * 24
|
6100 * 7300 * 2400
|
12
|
13200
| |
Class 10000
(ISO7)
|
ALCS6 * 8
|
2000 * 3000 * 2400
|
1
|
1100
|
ALCS 8 * 16
|
2440 * 4880 * 2400
|
2
|
2200
| |
ALCS 12 * 16
|
3660 * 4880 * 2400
|
4
|
4400
| |
ALCS 20 * 24
|
6100 * 7300 * 2400
|
8
|
8800
| |
Class 100,000
(ISO8)
| ALCS16 * 24 | 4880 * 7300 * 2400 | 2 | 2200 |
ALCS18 * 30 | 5480 * 9150 * 2400 | 4 | 4400 | |
ALCS20 * 42 | 6100 * 12800 * 2400 | 6 | 6600 |
Please contact with us for your best clean room solutions.
PRODUCT FEATURES:
Flexible assembly: Compared to the tradtitional clean booth it is easy to installation, cost effective with less investment and quick return, as it cost shorter construction period in the assembling frame by manufacturer.
Flexible assembly: Compared to the tradtitional clean booth it is easy to installation, cost effective with less investment and quick return, as it cost shorter construction period in the assembling frame by manufacturer.
Selected high quality material: import for the grind curtain and adjustable plastiv cup and universal wheel, convenience for installation and maintance.
Humanized structure: Compared to the clean bench it has the multi-function, which can be used as a unit or combined with another clean equipment together. Even you can assemble it on the production line to change dust-free production.
Flexibility: Less limitation or low requirements for the floor and spot situation, the iner space is enough to use and the frame canbe recycled
ANLAITECH BRAND MODULAR CLEAN ROOM, EASY INSTALLATION, QUALITY CERTIFIED, WELCOME TO CONTACT WITH US FOR FACTORY PRICE.
www.cleanroomffu.com
www.analitech.com
sales@anlaitech.com
没有评论: